这个报错这么解决呀:
The following Unit Operation blocks werecompleted with errors:B2
The following messages were issued during Input Translation:
INFORMATION THERE ARE HENRY COMPONENTS DEFINED IN THIS CASE, THE BINARY DATABANK WILL BE SEARCHED AUTOMATICALLY FOR ANY AVAILABLE HENRY CONSTANTS.
INFORMATION IN PHYSICAL PROPERTY SYSTEM THE PAIR PARAMETERS FOR ELECNRTL OPTION SET HAS BEEN RETRIEVED FROM DATABANK ENRTL-RK.
INFORMATION PURE COMPONENT PARAMETERS FOR SOME COMPONENTS ARE RETRIEVED FROM DATABANK ELECPURE. THESE PARAMETERS ARE USED WITH ELECNRTL METHOD. UNLESS YOU ENTER YOUR OWN PARAMETERS IN PROP-DATA PARAGRAPHS. PARAMETER PC RETRIEVED FOR COMPONENT H2SO4 PARAMETER TC RETRIEVED FOR COMPONENT H2SO4 PARAMETER ZC RETRIEVED FOR COMPONENT H2SO4 PARAMETER RKTZRA RETRIEVED FOR COMPONENT H2SO4 PARAMETER VC RETRIEVED FOR COMPONENT H2SO4 PARAMETER DGFORM RETRIEVED FOR COMPONENT H2SO4 PARAMETER DHFORM RETRIEVED FOR COMPONENT H2SO4 PARAMETER OMEGA RETRIEVED FOR COMPONENT H2SO4 PARAMETER THRSWT(ELEMENT/3) RETRIEVED FOR COMPONENT H2SO4 PARAMETER CPAQ0 RETRIEVED FOR COMPONENT HSO4- PARAMETER CPAQ0 RETRIEVED FOR COMPONENT SO4-- PARAMETER THRSWT(ELEMENT/3) RETRIEVED FOR COMPONENT H2O PARAMETER VLBROC RETRIEVED FOR COMPONENT CO2 PARAMETER PLXANT RETRIEVED FOR COMPONENT H2SO4 PARAMETER PLXANT RETRIEVED FOR COMPONENT H2O
The following messages were issued during Report Generation:
* WARNING WHILE GENERATING REPORT FOR STREAM: 'S2' LIQUID PHASE CALCULATIONS REQUESTED FOR A MIXTURE WHERE ALL COMPONENTS ARE DEFINED AS HENRY COMPONENTS (' GLOBAL '), YET AT LEAST ONE OF THEM IS SUB-CRITICAL (' CO2 '). FLASH CALCULATIONS MAY BE INCORRECT. CALCULATED PROPERTIES MAY BE UNRELIABLE DUE TO FLASH PROBLEM.
The following Unit Operation blocks werecompleted with errors:B2
The following messages were issued during Input Translation:
INFORMATION THERE ARE HENRY COMPONENTS DEFINED IN THIS CASE, THE BINARY DATABANK WILL BE SEARCHED AUTOMATICALLY FOR ANY AVAILABLE HENRY CONSTANTS.
INFORMATION IN PHYSICAL PROPERTY SYSTEM THE PAIR PARAMETERS FOR ELECNRTL OPTION SET HAS BEEN RETRIEVED FROM DATABANK ENRTL-RK.
INFORMATION PURE COMPONENT PARAMETERS FOR SOME COMPONENTS ARE RETRIEVED FROM DATABANK ELECPURE. THESE PARAMETERS ARE USED WITH ELECNRTL METHOD. UNLESS YOU ENTER YOUR OWN PARAMETERS IN PROP-DATA PARAGRAPHS. PARAMETER PC RETRIEVED FOR COMPONENT H2SO4 PARAMETER TC RETRIEVED FOR COMPONENT H2SO4 PARAMETER ZC RETRIEVED FOR COMPONENT H2SO4 PARAMETER RKTZRA RETRIEVED FOR COMPONENT H2SO4 PARAMETER VC RETRIEVED FOR COMPONENT H2SO4 PARAMETER DGFORM RETRIEVED FOR COMPONENT H2SO4 PARAMETER DHFORM RETRIEVED FOR COMPONENT H2SO4 PARAMETER OMEGA RETRIEVED FOR COMPONENT H2SO4 PARAMETER THRSWT(ELEMENT/3) RETRIEVED FOR COMPONENT H2SO4 PARAMETER CPAQ0 RETRIEVED FOR COMPONENT HSO4- PARAMETER CPAQ0 RETRIEVED FOR COMPONENT SO4-- PARAMETER THRSWT(ELEMENT/3) RETRIEVED FOR COMPONENT H2O PARAMETER VLBROC RETRIEVED FOR COMPONENT CO2 PARAMETER PLXANT RETRIEVED FOR COMPONENT H2SO4 PARAMETER PLXANT RETRIEVED FOR COMPONENT H2O
The following messages were issued during Report Generation:
* WARNING WHILE GENERATING REPORT FOR STREAM: 'S2' LIQUID PHASE CALCULATIONS REQUESTED FOR A MIXTURE WHERE ALL COMPONENTS ARE DEFINED AS HENRY COMPONENTS (' GLOBAL '), YET AT LEAST ONE OF THEM IS SUB-CRITICAL (' CO2 '). FLASH CALCULATIONS MAY BE INCORRECT. CALCULATED PROPERTIES MAY BE UNRELIABLE DUE TO FLASH PROBLEM.